As we work to deliver energy efficient buildings, one of the key challenges is ensuring new buildings meet performance expectations. In practice a “performance gap” can exist between the expected and actual energy performance and operational carbon emissions from buildings. This gap can be significant with research showing heating demand for new homes can be 100% - 150% than expected at the design stage.

In this article, we dig into the performance gap including:

  • the key potential causes of underperformance
  • how we can address these issues.
What are the causes of the performance gap?

The performance gap between the design and actual performance of buildings can occur for a range of reasons. Some of the most common relating to the insulation specification can include:

  • Product substitution – during construction, products can be substituted for a variety of reasons. This can cause underperformance where the specified product is replaced with a lower performing alternative such as less thermally efficient insulation, but this information is not passed onto the energy assessor and therefore not reflected in design performance expectations.
  • Unanticipated problem areas – in certain areas of the building envelope, unexpected issues can mean that the available space for insulation is reduced. This can mean thinner layers of insulation are used than required by the specification, or no insulation at all is installed in particularly challenging areas.
  • Thermal bridges –where construction details for insulation measures at junctions and around openings are not considered during the design phase, this can lead to higher than expected losses as a result of thermal bridges.
  • Poor workmanship – similarly, where insulation measures are fitted with gaps or cut inaccurately, it can provide paths for heat to easily by-pass the insulation layer leading to higher than anticipated heat losses.
How can we address the causes of the performance gap?

There are a range of solutions which can be deployed to address these potential issues.

Product substitution

If the insulation product within the original specification is unavailable, care should be taken to ensure the replacement provides an equivalent performance in key areas such as thermal and reaction to fire performance. Where this is not the case, building modelling should be updated to reflect this change. This will allow corrections to be made, for example, by fitting a greater thickness of insulation.

Problem areas

Where the available space is less than anticipated, problem solving solutions may be available to allow the required U-value to be met within the available depth.

For example, AlphaCore range products combine a Euroclass reaction to fire rating of A2-s1,d0 with a thermal conductivity of just 0.020 W/mK. This thermal conductivity is far lower than conventional façade insulation products with an equivalent reaction to fire rating. This can allow a project U-value to be met with a slimmer construction in problem areas where the available depth may be limited such as:

  • where the is a close boundary with another building
  • where the floor slab projects beyond the structural frame
  • where a lift shaft projects beyond the structural frame
  • where shear walls project beyond the structural frame.

Our OPTIM-R range of vacuum insulation panels (VIPs) can also provide a slim solution for challenging applications such as existing solid floors or roof terraces where an even transition must be maintained between internal and external floor heights. The VIPs have a thermal conductivity of just 0.007 W/mK, far lower than conventional alternatives. This can allow the desired thermal performance to be met with a very slim insulation system thickness.

The OPTIM-R E Inverted Roofing System features encapsulated VIPs which support easy manual handling and allow the desired U-value to be met with a slimmer system thickness than conventional extruded polystyrene (XPS) alternatives. 

Thermal bridges

To support best practice, and ease compliance, it is recommended to use designed details for insulation measures at key junctions where possible. These ensure that a clear process sequence is provided for the installation team to allow them to deliver a construction which effectively reduces heat losses. 

We have developed a range of calculated details for our Kooltherm K8 Plus Cavity Board, supporting designers to achieve workable details with low levels of heat loss. Click here to download the psi-values and CAD details.

Poor workmanship

Effective oversight of installations is also essential to ensure that insulation measures are correctly installed with no gaps or defects. Product training and installation guides can be a useful resource provided by manufacturers, enabling installers to understand proper installation processes and how to deal with any challenges appropriately without compromising overall performance. 

  • Related Articles

  • What are U-values, R-values and Lambda Values?
  • Types of Insulation - a Guide

Looking for more information on AlphaCore?

AlphaCore can allow U-values to be met with a slimmer construction in problem areas where the available depth may be limited
Click here
image of installed AlphaCore Pad

Start your project with us

Request a quote

Our Problem Solving Insulation Solutions

Find out more about our products
A microporous silica-based board used with rainscreen facades and soffits
Featured

AlphaCore Pad

A microporous silica-based board used with rainscreen facades and soffits

Optimum performance insulation solution for protected membrane flat roofs

OPTIM-R E Inverted Roofing System

Optimum performance insulation solution for protected membrane flat roofs

Optimum performance flat roof insulation for where space is limited

OPTIM-R Roofing System

Optimum performance flat roof insulation for where space is limited

Optimum performance floor insulation for where space is limited

OPTIM-R Flooring System

Optimum performance floor insulation for where space is limited

Talk to Us

How can we help you?
Send an Enquiry
Stay Updated
Contact us
Kingspan Insulation
Kingspan Technical Insulation
Kingspan Ireland
Kingspan Insulation
Kingspan Technical Insulation
Legal information
Cookie Policy and Control
Terms & Conditions of Website Use
Website Privacy Notice
Gender Pay Gap

© 2026 Kingspan Holdings (IRL) Limited, All Rights Reserved