The standard AS/NZS 4859.1.2018 defines the general criteria and technical provisions of thermal insulation materials for buildings in New Zealand and Australia. The latest New Zealand Building Code (NZBC) clause - H1 Energy Efficiency - stipulates the use of this standard to verify the thermal resistance (material R-value) of insulation materials. 

The updated AS/NZS 4859.1:2018 standard will see changes introduced to the way insulation products (bulk, reflective foil and rigid foam) are tested, as well as how thermal performance (material R-value) is calculated and declared. The biggest changes within the amended standard AS/NZS 4859.1:2018 are to do with thermal testing and formal declarations of performance labelling.

Compared to the previous suspended standard (AS/NZS 4859.1:2002), AS/NZS 4859.1:2018 contains new thermal testing requirements that are more stringent. This means the declared material R-values will decrease across the entire range of insulation products.

Lambda Value vs R-Value

Specifiers and builders need to be vigilant to ensure the products they’re specifying and buying meet the amended standard (AS/NZS 4859.1:2018). Here’s why:

• If the manufacturers and suppliers are not complying with the new standard, the advertised thermal values for their products may not be accurate, i.e. the stated values will be higher than they actually are.

• Specifying these non-compliant products will affect the thermal performance of the finished building. As a result, the building might not comply with the minimal required thermal performance under the NZBC H1 Energy Efficiency clause.

How to ensure you only specify insulation products that comply with new H1 Energy Efficiency standards

When verifying performance for rigid insulation (Phenolic PF, Polyisocyanurate PIR, Polyurethane PUR and Extruded Polystyrene XPS), it’s important to ask the product manufacturer/supplier the right questions. By asking the questions outlined below, you’re ensuring the information provided is accurate and compliant.

If the product manufacturer/supplier answers any of these questions incorrectly, or quotes a different or equivalent compliance standard, it’s likely their product does not comply with AS/NZS 4859.1.2018.

For example, one of the mandatory requirements detailed in AS/NZS 4859.1.2018 is the use of aged rigid insulation product samples in the thermal performance test. The mean test results are required to be statistically adjusted, so that the thermal conductivity and R-values will represent the thermal performance of the product after 25 years of ageing under normal in-service conditions.

Important questions to ask your insulation manufacturer/supplier:

Q&A

How to check insulation product labelling

As part of the AS/NZS 4859.1.2018 standard’s requirement, the insulation product’s label needs to include the following information:

• Statement of conformance to AS/NZS 4859.1.2018

• Material thermal performance ‘R-Value’ or ‘Declared ƛ-Value’ (thermal conductivity) are statistically derived using the R50/90 or ƛ50/90 method, respectively.

• The relevant temperature for the declared thermal values (15ºC for NZ)

It should be noted that ‘Construction R-value’ is no longer acceptable for product labelling.

Want to talk to an expert?

If you’d like help with understanding the new standards for insulation in New Zealand and the differences between material R-value and construction R-value, please call us on 0800 806 595 or email info@kingspaninsulation.co.nz

  • Related Products

  • Therma TR28
  • Therma TR26
  • Thermataper TT46
  • Related Products

  • STEICO Universal Dry
  • STEICO Universal
  • Related Products

  • Kooltherm K7 Pitched Roof Board
  • Kooltherm K17 Insulated Plasterboard
  • Kooltherm K12 Framing Board
  • Kooltherm K10 G2W White Soffit Board

Discover More

Kingspan Kainga Ora Case Study Hero

Bader Ventura Passive House Development

Kingspan Kooltherm K17 Insulated Plasterboard part of a ground-breaking new social housing project

Case Study5 min read

Start your project

Talk to us

Related Products

Learn more about the product
External wall insulation

Kooltherm K5 External Wall Board

External wall insulation

Soffit board suitable for ceiling and underfloor insulation
Featured

Kooltherm K10 G2 Soffit Board

Soffit board suitable for ceiling and underfloor insulation

High performance insulated plasterboard with a thin profile
Featured

Kooltherm K17 Insulated Plasterboard

High performance insulated plasterboard with a thin profile

Business Groups
Products
Knowledge & Inspiration
Tools & Services

© 2026 Kingspan Holdings (IRL) Limited, All Rights Reserved