Internal vs External Wall Insulation: When Should Each be Considered?

Fitting solid wall insulation can be an effective way to reduce heat losses from these properties, making them more comfortable and affordable to heat. However, there is no single ‘best’ solid wall insulation approach which works for every property. External Wall Insulation (EWI) is often considered a lower-risk and more straightforward option where it can be installed appropriately. At the same time, Internal Wall Insulation (IWI) or hybrid wall insulation (HWI) can provide effective solutions where external insulation is impractical or unsuitable. The most appropriate approach depends on building specific factors such as its construction, condition, exposure, ventilation, detailing and moisture risk.

Key points to consider with EWI

Whilst less complex than IWI installations, careful planning and detailing is still crucial to ensure EWI installations perform as intended and to prevent unintended consequences.

Key points which need to be considered include:

  • The condition of the existing building – the building should be appropriately assessed and any issues such as missing pointing, broken guttering, water ingress or dampness properly addressed before installation.

  • Roof overhangs – installing EWI systems will extend the walls outwards. Roof eaves and verges may need to be extended, or alternative appropriate detailing adopted, to ensure adequate weather protection and prevent rainwater entering behind the system.

  • Windows and doors – insulation should be returned around the reveals to ensure thermal continuity. Sills and thresholds may also need to be extended.

  • Penetrations & fittings – external fixtures, fittings and services attached to the building may need to be removed and refixed over the insulation system. Careful detailing is also needed around penetrations and elements such as flues to maintain weather protection and system performance.

One of two strategies are commonly adopted to achieve this:

  • Limiting moisture from entering the construction – here the IWI system is designed to reduce the amount of moisture entering the wall from internal spaces. This typically includes the use of insulated plasterboard systems, such as Kooltherm K118, and a well-detailed vapour control strategy to help limit moisture entering the wall from internal spaces.

  • Managing moisture within the construction – these systems are designed to allow small amounts of water to continue to enter the construction. They typically use insulation such as wood fibre and mineral fibre which allow vapour diffusion and can store small amounts of moisture (known as buffering).

Neither approach is universally better or safer in every circumstance. The most appropriate solution for a particular project will depend on a variety of project specific factors and should be determined through a whole building assessment.

Regardless of which approach is adopted, careful detailing is essential to support a successful installation. Particular attention is needed at:

Stay updated

  • Application
  • Wall
  • Date Published
  • Last Updated
  • Products
  • Kooltherm K118 Insulated Plasterboard

Start your Project

Large/Commercial
Small/DIY Projects

Why is it important to insulate solid walled properties?

Improving the energy performance of the approximately eight million solid walled homes in the UK is a key step in meeting our net zero emissions targets and addressing fuel poverty. These properties, which were typically built pre-1930, can allow much greater levels of heat loss through the external walls than with cavity walled homes. Installing solid wall insulation (SWI) can significantly improve comfort, reduce energy demand and bills and support the installation of low carbon heating systems (such as heat pumps) within these properties.

Understanding solid wall insulation options

External wall insulation (EWI) involves applying insulation, such as Kooltherm K5 External Wall Board, to the outside of the building behind a render or cladding system.

Internal wall insulation (IWI) is installed on the inside face of exterior walls. Insulation options can include insulated plasterboard (such as Kooltherm K118 Insulated Plasterboard), wood fibre and mineral fibre insulation. The most suitable system and materials will depend on the approach taken to manage moisture within the wall and the wider building context.

Hybrid wall insulation (HWI) features a combination of EWI and IWI systems in different areas of the building.

Whilst all these approaches aim to improve the thermal performance of walls, they interact differently with the existing building and bring different considerations.

Whichever approach is adopted, this work should be carried out as part of a whole building approach and best practice is that all external walls are insulated as part of the installation to reduce thermal bridging and localised cold spots.

  • Below DPC – to help reduce heat loss and thermal bridging at the base of the wall, insulation should generally extend to at least ground level and, where practicable, below ground level using suitable moisture-resistant materials such as Kingspan GreenGuard GG300.

  • This work should be completed as part of a whole building approach.

    When external insulation isn’t possible

    Whilst EWI can offer a number of advantages for solid wall retrofits, these systems aren’t always suitable. Common reasons for this include:

    • Planning restrictions which limit alternations to the exterior or visible frontage of homes (typically for listed buildings or those located within conservation zones).

    • Physical limitations, such as proximity to boundaries or neighbouring buildings.

    • The desire to retain the existing external appearance of the building.

    In these cases, IWI systems can provide an alternative.

    • window and door openings

    • floor and ceiling junctions

    • service penetrations

    • interfaces with other building elements.

    Learn more about what needs to be considered before fitting IWI.

    Considering a hybrid approach

    In some cases, a combination of external and internal insulation may be the most practical solution.

    For example, in conservation areas, the use of EWI may be acceptable in parts of the building which are not visible from the road, whilst IWI can be used to retain the original frontage.

    In HWI applications, careful consideration needs to be given to the junction between the IWI and EWI systems. Where this occurs at a corner, the IWI system should typically be continued to ensure an overlap of at least 300 mm to prevent thermal bridging.

    The importance of a whole-building approach

    Solid wall insulation projects should be supported by an appropriate whole-building assessment, informed by BS 40104 and considering the principles within BS 5250 and, where relevant, retrofit frameworks such as PAS 2035/2038, which promote coordinated, risk-managed whole-dwelling retrofit assessment, design and sequencing. As part of the process, an appropriate assessment and survey should be carried out on the property, considering aspects such as:

    • the condition and construction of the building

    • its exposure to weather

    • how it is used, heated and ventilated

    • how different building elements and retrofit measures interact.

    This process allows project teams to identify the most appropriate retrofit strategy and to ensure that issues relating to condition, moisture, ventilation or detailing can be properly addressed before insulation is installed. This assessment-led, building-specific approach is essential to achieving successful long-term retrofit outcomes.

    Summary

    Internal, external and hybrid wall insulation can all play an important role in improving the performance of solid wall buildings.

    EWI, IWI and HWI approaches each offer different advantages and constraints. In many situations, EWI can provide a straightforward and robust solution, particularly where continuity of insulation and reduction of thermal bridging can be more readily achieved. However, the most appropriate approach will depend on the building, its condition, construction, exposure, use and wider retrofit strategy.

    All solid wall insulation projects should form part of a whole-building approach which carefully considers aspects such as the building’s condition, construction, exposure, ventilation and moisture behaviour, and develops a coordinated package of retrofit measures to achieve successful outcomes.

    Successful retrofit outcomes rely on good assessment, thoughtful design, appropriate detailing and high-quality installation.

    Kooltherm K5 External Wall Board

    Our internal wall & external wall insulation solutions

    Phenolic external wall insulation installed on a brick wall house

    Why external wall insulation is often preferred

    Where it can be used, EWI is often considered the more straightforward and robust solution for insulating solid walls. As the insulation wraps around the outside of the building, it is typically easier to achieve a continuous layer of insulation with EWI than IWI and details are often less complex.

    This approach also means that the existing wall remains warm, meaning it is less exposed to internal temperature drops and wind-driven rain. This can reduce moisture risk associated with colder wall structures and thermal bridging in many situations.

    For these reasons, external insulation can offer a relatively robust and lower risk solution in many situations.

    Learn more about EWI systems.

    Someone wearing PPE installing internal wall insulation

    The role of internal wall insulation

    IWI offers a practical route to upgrading the thermal performance of solid walls without altering a building’s external appearance.

    When adopting this approach, it is important to be aware that insulating internally will change how the wall behaves. The existing wall becomes colder as it is less exposed to the warmth from the home and this affects how heat and moisture move through the construction.

    This means careful consideration needs to be given to how moisture will move through and interact with the wall following retrofit, alongside the detailing and quality of installation needed to prevent potential issues with condensation and damp.

    Talk to us

    What can we help you with?
    Click here to request a sample
    1. Home
    2. Internal vs External Wall Insulation: When Should Each Be Considered?
    Premium performance internal wall insulation
    Featured

    Kooltherm K118 Insulated Plasterboard

    Premium performance internal wall insulation
    Premium performance external wall insulation

    Kooltherm K5 External Wall Board

    Premium performance external wall insulation