1. Home
  2. How to install K-Roc Rainscreen Slab

How to install K-Roc Rainscreen Slab

  • Sector
  • Construction
  • Date Published
  • last Updated
  • Products
  • K-Roc Rainscreen Slab
K-Roc mineral fibre installation

Rainscreen façades are a popular choice for mid- and high-rise developments across Ireland. K-Roc Rainscreen Slab provides a versatile insulation solution for these applications. The rock mineral fibre slabs achieve a thermal conductivity of 0.034 W/mK and have a Euroclass A1 rating. 

When fitting this insulation, it is important to be aware that all rainscreen façade systems are proprietary and use a range of fixing approaches to support the external façade. Similarly, the underlying structure may use steel or concrete framing, or a combination of the two. In this article, we look at best practice when installing K-Roc as part of a typical ventilated rainscreen with aluminium cladding on a steel frame construction, however, it is important to refer to the rainscreen system provider for specific installation guidance on each project.

Tools you will require
  • Hard steel blade saw
  • Dust mask
  • Impact driver or SDS drill
  • Suitable mechanical fixings and support anchors 
Preparation

Prior to installing the rainscreen insulation, the steel framing system (SFS) should have been fixed and levelled with a suitable insulation, such as K-Roc Framing Slab fitted snuggly between the studs with no gaps. A vapour control layer should typically be fitted internally, followed by the drylining. 

Externally, a cement particle board is fixed to the SFS followed by a breather membrane and weathering seals. Helping hand / support brackets for the outer cladding are then fitted either using c-channel or directly to the SFS studs. Cavity barriers should also be fitted both vertically and horizontally in line with the Building Regulations.

U-value calculation

If you need to confirm the thickness of K-Roc Rainscreen Slab and K-Roc Framing Slab to achieve your project U-value, our experienced technical service department can carry out the calculation and condensation risk analysis.

Request a U-value calculation

Installing the insulation

The K-Roc slabs should be installed in a break bonded pattern so that horizontal joints are offset. The slabs should lightly butt against one another with no gaps between the adjoining slabs or the slabs and the substrate. 

Cutting

The slabs should be cut neatly to fit around fixings, brackets and junctions with care taken to ensure there are no gaps in the insulation layer. This can be done with a standard hard steel blade saw. When cutting the insulation, workers should also wear dust masks in line with CDM Guidance. 

Fixings

The slabs should be secured with suitable metal mechanical fixings with polypropylene support anchors/washers. A minimum of three fixings per m2 should be fitted. The centre fixing of each slab should be metal with metal spreader plate. The remaining 2 fixings and spreader plates can be plastic if required. Fixings should have a minimum head diameter of 70 mm. 

The type and number of fixing may vary depending on a range of factors including:

  • location
  • local topography
  • the height and width of the wall
  • the wall structure and cladding system
  • the type of support system used to attach the cladding.

For this reason, the fixing requirements should always be assessed in accordance with I.S. EN 1991-1-4: 2005 in the Republic of Ireland or BS EN 1991-1-4: 2005 + A1: 2010 in Northern Ireland.

In all cases, the fixings should be evenly spaced across the rainscreen insulation.

For standard sheet metal cladding, fixings and further guidance can be obtained from Ejot or SFS. Where a masonry façade is used, a suitable restraint system, such as the Ancon 25/14 Restraint System, should be installed in line with their guidance.

Daily practice

At the end of the working day or during extended interruptions, the slab edges and joints should be protected. 

Installation of the outer cladding should be scheduled so that the slabs are left exposed for the shortest possible time. If the slabs are exposed to wet conditions, then they should be allowed to dry as much as possible and properly inspected so that any damaged or saturated slabs can be replaced.

Storage 

Where possible, K-Roc slabs should be stored inside a building. Where this is not possible, they should be stacked clear of the ground and covered with a suitable opaque polythene or weatherproof tarpaulin. 

Outer cladding installation

Once the insulation layer is fitted and secured, T and L sections are typically fixed to the supporting brackets. The outer cladding can then be secured in line with manufacturer guidance.

Further guidance

If you have further questions about installing K-Roc Rainscreen Slab, refer to the product literature or contact our experienced Technical Service Department.

  • Related Products

  • K-Roc Rainscreen Slab
  • K-Roc Framing Slab

K-Roc Rainscreen Slab

Download the brochure
Download PDF

Discover More

Kingspan Insulation Castleblayney Factory Airview

AVCP – What does it mean?

In this article we will look at what AVCP is and the different systems (levels) of AVCP.

Knowledge Article5 min read
Kingspan Avoidable Costs How Thinner Insulation Can Help Save Money On Overall Construction Costs Article 3:4

What is the performance gap?

What is the performance gap, what causes it and how can we prevent it?

Knowledge Article5 min read
What Are U-Values, R-Values And Lambda Values Article- 4:3

What are U-values, R-values and Lambda Values?

Lambda, R-values, U-values, Thermal Conductivity and Thermal Resistance simplified in one article

Knowledge Article4 min read
kingspan-who-we-are

Types of Insulation - a Guide

We manufacture five types of insulation for walls, floors and roofs.

Knowledge Article4 min read

Start your project with us

Request a quote

Our mineral fibre rainscreen insulation solutions

Find out more about our products
Rock mineral fibre for use behind rainscreen façades

K-Roc Rainscreen Slab

Rock mineral fibre for use behind rainscreen façades

Rock mineral fibre for use within steel frame systems

K-Roc Framing Slab

Rock mineral fibre for use within steel frame systems

Talk to Us

How can we help you?
Send an Enquiry
Stay Updated
Contact us
Kingspan Insulation
Kingspan Technical Insulation
Kingspan Ireland
Kingspan Insulation
Kingspan Technical Insulation
Legal information
Cookie Policy and Control
Terms & Conditions of Website Use
Website Privacy Notice
Gender Pay Gap

© 2026 Kingspan Holdings (IRL) Limited, All Rights Reserved